I. Introduction of Electromagnetic Sewage Flowmeter

EMFM series electromagnetic sewage flowmeter can be widely used in the measurement of volumetric flow of conductive liquids in municipal water supply, steel, petroleum, chemical, electric power, industry, water conservancy, water administration and water resources. It is especially suitable for channels and small river channels. Sewage metering for flow measurement and environmental treatment.

Second, the characteristics of electromagnetic sewage flowmeter

1. The electromagnetic sewage flowmeter has a simple structure, is reliable, and has a long service life (and is suitable for measuring seawater) 2. There are no moving parts and resistance parts in the measuring tube, no pressure loss, and no blockage 3. Reliable measurement and strong anti-interference ability 4. Small size, light weight, convenient installation, low maintenance 5. Wide measuring range, measurement is not affected by changes in fluid temperature, density, pressure, viscosity, conductivity, etc. 6. It can be retrofitted and installed in old pipes, Simple construction and installation, small amount of work 7. Low cost and installation cost compared to general electromagnetic flowmeters, especially suitable for large and medium diameter pipeline flow measurement 8. Adopting advanced processing technology, solid-state packaging, long life, and good meter measurement accuracy And stability

Third, the main technical performance indicators of electromagnetic sewage flowmeter

Velocity measurement range: (0.05-10) m / s Measuring pipe diameter: DN (32-6000) mm Instrument accuracy: Class 1.0 Working pressure: ≤1.6MPa Medium temperature: 0-80 ℃ Power consumption: ﹤ 15VA Protection level: IP68 Connection method: Flange connection electrode material: Molybdenum-containing stainless steel OCr18Ni12Mo2Ti, Hastelloy B, Hastelloy C, titanium Ti, tantalum, etc.

Fourth, the electromagnetic sewage flowmeter installation requirements

1) Choice of installation environment of electromagnetic sewage flowmeter: It should be far away from equipment with strong electromagnetic field, such as large motors, large transformers, large frequency converters, etc. There should be no strong vibration at the installation site, the pipelines should be fixed firmly, and the ambient temperature should not change much (to prevent the two-phase change of solid and liquid). The installation environment should be easy to install and maintain. 2) Selection of the installation location of the electromagnetic sewage flowmeter: The installation location must ensure that the pipeline is always filled with the measured liquid. Choose a place with a small liquid flow pulse, that is, away from local resistance parts such as pumps, valves, elbows, etc. When measuring two-phase (solid, liquid and gas, liquid) liquids, choose a place where phase separation is unlikely to occur. The inner diameter or perimeter of the pipe to be measured is easy to measure, and the ovality should be small. 3) Length of straight pipe section of electromagnetic sewage flowmeter: The length of the straight pipe section on the upstream side of the sensor installation pipe should be greater than or equal to 10D, and the downstream side should be no less than 5D (D is the diameter of the pipe being tested). 4) Flow control valve and regulating valve: The flow control valve should be installed in the pipeline to be tested on the upstream side of the sensor, and the flow regulating valve should be installed on the downstream side of the sensor. When flow, the flow control valve should normally be fully open.

Product Features of Electromagnetic Sewage Flowmeter

Full digital processing, strong anti-interference ability, reliable measurement, high accuracy, and flow measurement range up to 150: 1 l Ultra-low EMI switching power supply, suitable for a wide range of power supply voltage changes, and good EMI performance. l 16-bit embedded microprocessor, fast calculation speed, high precision, programmable frequency low frequency rectangular wave excitation, improve the stability of flow measurement and low power consumption. l Adopt SMD device and surface mount (SMT) technology, high circuit reliability. l There are no moving parts and no choke parts in the pipeline, and there is almost no additional pressure loss in the measurement. l The range can be modified online at the site according to the actual needs of the user. l The measurement result has nothing to do with physical parameters such as velocity distribution, fluid pressure, temperature, density, and viscosity. l High-definition backlit LCD display, full Chinese menu operation, easy to use, simple operation, easy to learn and understand. l RS485, RS232, Hart and Modbus digital communication signal output. (Optional) l With self-checking and self-judgement functions. l Hourly total recording function, which records the total amount of flow in hours, which is applicable to the time-sharing measurement system (optional) Calculate the amount, there is always built-in power-down always, can record 16 times of power-down time. (Optional) l Infrared handheld operator, 115KHZ communication speed, all functions of long-distance non-contact operation converter (optional)

Choice of electrode materials for electromagnetic sewage flowmeter

The material of the electrode should be selected according to the corrosiveness of the fluid being tested. Please refer to the relevant manual. Corrosion test should be performed for special fluids


material

Code

Corrosion resistance

不锈钢 316L stainless steel

V

适用于工业、生活用水,原水井水,城市污水等中性溶液 1Suitable for industrial, domestic water, raw well water, urban sewage and other neutral solutions
弱腐蚀性酸、碱、盐介质如碳酸、醋酸等 2 Weakly corrosive acids, alkalis, salt media such as carbonic acid, acetic acid, etc.

C Hastelloy C

HC

适用于耐氧化性酸,如硝酸、混酸、铬酸与硫酸的混合物 1 Suitable for oxidation resistant acids, such as nitric acid, mixed acid, mixture of chromic acid and sulfuric acid
耐氧化性盐类或其它氧化剂环境的腐蚀如 Fe Cu 2 Corrosion resistance to oxidative salts or other oxidant environments such as Fe , Cu
对海水、碱溶液,氧化物溶液有极好的耐腐蚀性 3Excellent corrosion resistance to seawater, alkali solution and oxide solution
不适用:盐酸 4 Not applicable: hydrochloric acid

B Hastelloy B

HB

对于非氧化酸、碱、盐如硫酸、磷酸、氢氟酸有良好的腐蚀性 1Good corrosion resistance to non-oxidizing acids, bases, salts such as sulfuric acid, phosphoric acid, hydrofluoric acid
不适用:硝酸 2 Not applicable: Nitric acid

titanium

Ti

Resistant to seawater, all kinds of chlorides, suddenly hypochlorite and many kinds of hydroxides

Tantalum

Ta

With the exception of hydrofluoric acid, it is resistant to almost all chemical media. But expensive

platinum

Pt

Suitable for all acid and alkali salt solutions (fuming sulfuric acid and nitric acid)

Tungsten carbide

W

Has excellent abrasion resistance and is specially used for abrasive media such as mud and pulp

Selection of lining materials for electromagnetic sewage flowmeters

The lining material should be selected according to the corrosive wear and temperature of the tested medium


Lining material

Corrosion resistance

Operating temperature

Scope of application

Ne Neoprene Ne

Resistant to general low concentrations of acid and alkali salts

70 -20 70

Low concentration acid and alkali salts in industrial water and sewage

PO Polyurethane rubber PO

Has excellent abrasion resistance, special for strong abrasive slurry, non-corrosive

60 -10 60

Liquids containing solid particles (cement slurry, etc.)

FEP FEP

耐热耐腐蚀性与 PTFE 相当 1 heat and corrosion resistance equivalent to PTFE
机械强度高,抗磨损性能好 2High mechanical strength and good anti-wear performance
内表光滑,不易粘附沉淀物 3The inner surface is smooth, and it is not easy to adhere to sediment
有很好的耐负压,抗真空作用 4 has good resistance to negative pressure and vacuum

180 -40 180

All fluids except for abrasive media such as mortar. PTFE 一样,能用于饮料等有卫生要求的介质 Same as PTFE , can be used in beverages and other hygienic media

PTFE Teflon PTFE

Corrosion resistance to almost all chemical media, poor wear resistance

 

 